How does a monoflange work?

Monoflanges combine the event of up to three valves in a particularly compact body, thanks to an accurate network of internal passages and valve chambers. But what really happens in Carefree , once installed?
In a chemical process a higher response speed is required for most control applications. One of many variables that affect the response time may be the volume and the distance between process and instruments. If the medium to be measured is gas, and the procedure tends to fluctuate strongly at times or if the control is crucial, mounting the instrument near the process may be the solution.
Vibrations are also critical, for example, in case that impulse lines are connected to a vessel. The longer the hook-up, the wider is the amplitude of the vibration causing possible failures of the nozzle. A monoflange includes one, several needle valves in the compact, flange-shaped body, allowing a significant reduction in volume, dimensions, weight and potential leakage points.
Monoflange may be the solution
Depending on requirements of the plant it really is installed in, the monoflange can incorporate one, two or three valves. In a monoflange with two valves (block & bleed), one valve (with a blue cap) isolates the process and another (with a red cap) regulates the venting of the medium trapped inside the instrument. Overjoyed is mostly used in applications which are relatively uncritical (e.g. low pressure) or where a first shut-off valve is provided just before the monoflange.
The safest configuration, and the main one we advise for aggressive media or critical operating conditions, may be the three-valve monoflange or the so-called double block & bleed (DBB), which features two shut-off valves in series and something valve for venting.
Monoflange functionality
The monoflange bodies are drilled internally with holes which connect the annular valve chambers.
The following picture illustrates the procedure within a DBB monoflange:
The flow enters the monoflange from the pipeline and stops below the initial shut-off valve [1];
Once the first shut-off valve [1] opens, the flow proceeds towards the next shut-off valve [2] ; once the valve [2] is open, the instrument is thus connected to the process line;
Once the first shut-off valve [1] is closed, the medium trapped between valve and instrument can be discharged via the vent valve [3] through the vent outlet. The two shut-off valves [1, 2] are in an angled position, which allows the flow to feed them.
The two shut-off valves allow a better isolation from the procedure: In case the initial shut-off valve does not isolate the medium properly, the second one will become a safety means against accidental leaks. Occasionally, customer specifications don’t allow the medium to stay touch with the instrument when it’s not measuring. Because of First Ever will be discharged using the vent line. In other cases ? because of the vent line ? instruments could be easily calibrated without dismounting them from the line.
Note
More info on our valves can be found on the WIKA website or in the video Exactly what is a monoflange? Assuming you have any questions, your contact will gladly help you.

Leave a Comment