The significance of supervised monitoring modules used in management and monitoring of extinguishing techniques

In many locations from chemistry laboratories to industrial facilities, to be able to guarantee the protection of life and property against a potential fireplace hazard, extinguishing systems are used in addition to detection and alarm methods. It is also extraordinarily essential that the extinguishing systems installed can be triggered by the fire extinguishing management panel, in order to get rid of a attainable fireplace with early intervention.
In order to meet these needs, and with 35 years of sectoral knowledge and expertise, Mavili Elektronik offers:
Maxlogic Conventional Fire Extinguishing Control Panel working in accordance with the cross-zone detection precept;
Maxlogic Extinguishing Status Indicator Unit, which allows the distant performance of the symptoms and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which permits the extinguishing process to be began manually and remotely; and
to guarantee that the extinguishing process could be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these gadgets are produced using surface-mount know-how and are geared toward making the automation of the extinguishing system and fireplace and fuel detection system good.
Image copyright: Mavili
Mavili Elektronik develops its products by at all times contemplating the wants of the set up. In instances that require the mixing of the extinguishing system with the clever addressable fire detection system, it supplies options through the monitoring modules that even have a ‘supervised’ choice.
Supervised monitoring modules play an necessary role in controlling the continuity of the cable connection between the loop and the extinguishing system. เกจวัดแรงดันอากาศ to detect a potential open or brief circuit within the wiring between the contact monitoring modules and the peripheral methods could cause disruption of the triggering, with potentially crucial penalties. For this purpose, when choosing monitoring modules, it ought to be taken into account that they’ve supervised features.
เครื่องมือใช้วัดความดัน : Mavili
Since Maxlogic clever addressable fireplace detection and alarm management panels are continually speaking with ‘supervise’ contact monitoring modules related to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it easier to monitor conditions such as open circuits and brief circuits which will happen in the system. Many duties may be performed within the fire extinguishing set up, such because the control and monitoring of all valves that can interrupt the flow of water, water flow alarm switches, stress switch, and electric or diesel hearth pumps.
By including two contact monitoring modules to 2 separate relay outputs located above the Maxlogic Conventional Fire Extinguishing Control Panel, one of the modules can be utilized to regulate errors and the other to manage the fireplace situation, monitoring and management of the extinguishing system via an clever addressable fire detection and alarm system can be carried out successfully.
For extra information, go to www.mavili.com.tr/en
Share

Leave a Comment